RL-9047

 3-Digit Combination Cam Lock

With reset-button operation, no-master-key design, and decoder-tool support for forgotten codes, RL-9047 provides a simple mechanical locking solution for cabinet combination lock, locker combination lock, and cam lock replacement projects.


Product Overview

RL-9047 is a compact mechanical 3-digit combination cam lock designed for keyless access in cabinets, lockers, mailboxes, drawers, equipment panels, and shared storage applications. It allows users to lock and unlock with a personal combination code, helping reduce the need for physical key management in commercial, facility, and OEM / ODM storage projects.

Unlike keyed cam locks, RL-9047 does not require users to carry, manage, or replace physical keys. This makes it suitable for projects where lost keys, spare-key tracking, or master-key control may pose management issues.

RL-9047 is especially suitable for cabinet combination locks, locker combination locks, mailbox locks, and compact storage applications. It can be used in new product designs or cam lock replacement projects when the mounting hole, panel thickness, cam direction, and installation structure match the required specification.

No Master Key Design with Decoder Support

RL-9047 does not support a master key. This design helps reduce physical key management and avoids risks caused by lost or uncontrolled master keys.

If the combination code is forgotten, a decoder tool/code finder can be used by trained personnel to retrieve the code. This provides maintenance teams with a practical way to support users without relying on a physical override key.

Customized Application Experience 

REAL’s customized lock mechanism has been applied in public-use safety container applications in the Japanese market, helping support controlled access and reduce the risk of unauthorized opening or foreign substance contamination.

For customized applications, the lock mechanism can be redesigned according to the product structure, usage environment, and testing requirements. In one public-use safety container project, the lock design was adapted with an internal dial-covering structure to support waterproof testing requirements.

For projects requiring specific waterproof or dustproof performance, testing or certification arrangements, such as IP69K, may be discussed according to customer requirements, product design, application environment, and project scope.

RL-9047 comparison chart highlighting key advantages such as no batteries, no physical key, easy installation, solid metal design, resettable code, compact cam lock format, 5-year warranty, and decoder support for keyless cabinet and locker applications.


RL-9047 dimension drawing showing the 3-digit combination cam lock from multiple angles, including front size, side profile, barrel length, and installation-related dimensions for cabinet, locker, and storage compartment applications.

FeaturesDescription
Keyless Mechanical AccessOperated by a 3-digit combination code without a physical key.
No Master Key DesignReduces physical key management and the risk of lost master keys.
Reset Button OperationUsers can set or change the combination code through the reset button.
Decoder Tool SupportForgotten codes can be retrieved with a decoder tool ( code finder ) by trained personnel.
Compact Cam Lock FormatSuitable for cabinets, lockers, mailboxes, drawers, small storage compartments, and equipment panels.
Zinc Alloy Lock BodySolid, durable lock body suitable for daily-use mechanical locking applications.
Up to 1,000 CombinationsThe 3-digit dial system provides up to 1,000 possible combinations.
No Battery RequiredFully mechanical design requires no battery, wiring, or electronic system.
5-Year WarrantyDesigned for long-term mechanical use with 5-year warranty support.
Customized Application SupportCan be redesigned/customized for cabinet, locker, mailbox, equipment, or special container applications.
Testing Support Upon RequestProject-based testing or certification arrangements, such as IP rating(Ingress Protection Rating), may be supported according to customer requirements.

RL-9047 mounting and size diagram showing the lock front dimensions, installation hole reference, and barrel length options for different cabinet, locker, mailbox, or storage compartment applications.

Main Specifications

ItemSpecification
Model No.RL-9047
Product Name3-Digit Combination Cam Lock
Lock TypeMechanical Combination Cam Lock
Combination Type3-digit mechanical combination
Combination QuantityUp to 1,000 combinations
Code ResetReset Button
Master KeyNot supported
Code RecoveryDecoder tool / code finder available
Key RequiredNo physical key required
Lock Body MaterialZinc alloy
Standard FinishElectronic black
Other ColorsMay be available upon request
Applicable Door / Panel Thickness1–29 mm
Mounting-Hole DimensionØ19 mm, flat side 16 mm
Front Size54 mm × 46.8 mm
Lock Body Depth19.1 mm + barrel length
Warranty5 years
Logo StickerAvailable upon request

Barrel Length and Door Thickness

Barrel LengthSuitable Door / Panel Thickness
16 mmUp to 7 mm
22 mmUp to 13 mm
36.6 mmUp to 29 mm

Mounting-Hole Dimension

ItemSpecification
Mounting Hole DiameterØ19 mm
Flat Side16 mm
Installation TypeSuitable for selected standard cam lock mounting holes
Installation NotePlease confirm the mounting hole size, panel thickness, cam direction, and installation structure before ordering.

 

Material and Finish

ItemSpecification
Lock BodyZinc alloy
Standard FinishElectronic black
Other Finish / ColorMay be available upon request
Surface / AppearanceCompact mechanical lock body suitable for cabinet and locker applications

Available Options

OptionDescription
FinishStandard electronic black; other colors may be available upon request
Door / Panel ThicknessSuitable for 1–29 mm
Code Reset TypeReset Button
Decoder ToolAvailable for forgotten code retrieval
Cam OptionsDifferent cam lengths and configurations may be available according to installation needs
Cam Turning DirectionCan be configured according to the required lock / open direction
Logo StickerAvailable upon request
Customized DesignProduct structure may be adjusted for special applications
Testing / Certification SupportProject-based testing, such as IP69K, may be arranged upon request

 

No Master Key + Decoder Support

ItemDescription
Master KeyRL-9047 does not support a master key.
Main BenefitHelps reduce physical key management and lost master key risks.
Code RecoveryA decoder tool / code finder can be used by trained personnel to retrieve forgotten codes.
Recommended UseSuitable for applications where keyless access is preferred, and maintenance teams can manage code recovery when needed.

 

Customization and Testing Support

RequirementSupport Direction
OEM / ODM integrationLock structure may be adjusted according to cabinet, locker, mailbox, or equipment design.
Safety container applicationCustomized lock mechanisms can support controlled-access container applications.
Moisture / waterproof requirementTesting or design review may be discussed according to the project environment.
IP rating requestIP rating or other testing may be arranged based on project scope and customer requirements.
Color / branding requirementOther colors or logo sticker options may be discussed upon request.

Applications

ApplicationSuitable Use
CabinetsOffice cabinets, storage cabinets, furniture cabinets, equipment cabinets
LockersSchool lockers, gym lockers, workplace lockers, staff lockers, facility lockers
MailboxesMailbox-style storage compartments in residential or commercial buildings
DrawersDrawer units and furniture compartments requiring keyless access
Equipment PanelsAccess panels, machinery covers, utility boxes, and equipment enclosures
Storage CompartmentsSmall storage boxes, shared-use compartments, and compact storage units
Safety ContainersCustomized controlled-access container applications
OEM / ODM ProjectsProduct integration for cabinet makers, locker suppliers, and equipment manufacturers

RL-9047 installed on mailbox-style lockers, providing compact keyless access for shared storage compartments in residential, commercial, or facility management environments.RL-9047 installed on a large-scale mailbox-style locker system, providing compact keyless access for shared storage compartments in residential buildings, commercial facilities, offices, and managed spaces.

 


 

QuestionAnswer
What is RL-9047 used for?RL-9047 is suitable for cabinets, lockers, mailboxes, drawers, equipment panels, storage compartments, and customized safety container applications.
Does RL-9047 require a key?No. RL-9047 is operated by a 3-digit combination code.
Does RL-9047 support a master key?No. RL-9047 does not support a master key.
What happens if the code is forgotten?A decoder tool/code finder can be used by trained personnel to retrieve the forgotten code.
Can the code be reset?Yes. RL-9047 uses a reset button design for code setting.
What mounting hole does RL-9047 fit?RL-9047 fits Ø19 mm mounting holes with a 16 mm flat side.
What door thickness can RL-9047 support?RL-9047 is suitable for door or panel thickness from 1–29 mm.
What is the standard finish?The standard finish is electronic black. Other colors may be available upon request.
Can RL-9047 be customized?Yes. RL-9047 can be customized for specific product structures or application requirements.

Why is the RL-9047 combination lock not functioning properly?

Ensure that the RL-9047 lock is installed strictly according to the technical specifications outlined in the user manual. Incorrect installation—particularly misalignment or improper mounting of rear components—can lead to mechanical failure or non-responsiveness. Verifying all assembly steps is essential to ensure proper lock performance.

🔧 Troubleshooting Steps:

  1. Recheck installation orientation:
    Ensure that the lock body and number dials are aligned according to the instructions in the manual.

  2. Verify rear component placement:
    Confirm that all rear components—such as the mounting plate and brackets—are correctly installed and properly seated in position.

  3. Avoid overtightening screws:
    Excessively tight screws may interfere with the internal mechanism and cause the lock to malfunction. Tighten screws moderately by hand.

  4. Perform a functional test:
    Before mounting the lock onto the cabinet or door, test the dial rotation and knob operation independently to ensure smooth functionality.

How to Retrieve the Combination Code if You Forget It?

Insert the decoder into the exam position beside the dial and press lightly while holding it steady. Slowly rotate the dial until the decoder sinks into the exam hole position. Once it sinks down, the correct number for that dial has been identified. Repeat the same procedure for each dial until the complete opening code is found.

Important Notice:
The factory default code is usually set to 0-0-0. After retrieving the correct combination, it is recommended to reset the code back to 0-0-0 first, then set a new personal combination according to the product instructions.

RL-9047 decoder code finder operating instruction for forgotten combination recovery

If the issue persists, we recommend recording a short video of the installation and contacting us for further assistance.


RL-9047 Installation and Operation

How to Use the RL-9047 Combination Cam Lock

 

How to Install the RL-9047 Combination Cam Lock

 

RL-9047 3-Digit Combination Cam Lock Overview

0