RL-9046B
IP59K Keyless Combination Locker Lock
The RL-9046B is a mechanical keyless combination locker lock designed for commercial lockers, cabinets, and shared-use storage systems.
The lock provides up to 10,000 possible code combinations, clear open and close indicators, front-side code retrieval support, and left- or right-hand installation. Its fully mechanical design requires no batteries, wiring, access cards, or electronic programming.
RL-9046B has passed SGS testing for IP59K dust and water protection.
SGS-Tested IP59K Protection
Tested separately to IP5X dust protection and IPX9K high-pressure water protection requirements.
10,000 User-Set Combinations
The four-digit mechanical combination mechanism provides up to 10,000 possible code combinations.
Combination Access and Override Key Management
Users can operate the lock with a personal code, while authorized personnel retain override key access for management, maintenance or emergency opening.
Battery-Free Mechanical Operation
No batteries, wiring, access cards, or electronic programming are required.
Front-Side Code Retrieval Support
The designated management mechanism can assist authorized personnel with forgotten-code situations.
Clear Open and Close Indicators
Visual indicators help users identify the lock's operating status.
Left- or Right-Hand Installation
Available for different locker and cabinet door opening directions.
Wide Door Thickness Range
Suitable for door or panel thicknesses from 1 to 33 mm.
SGS-Tested IP59K Dust and Water Protection
RL-9046B was independently tested by SGS Taiwan for dust and high-pressure water protection.
The IP59K designation used on this product page represents the combination of two separate tests performed on the submitted RL-9046B sample:
- IP5X dust protection test
- IPX9K high-pressure and high-temperature water protection test
For the IP5X dust test, the sample was exposed to talcum powder for eight hours in accordance with IEC 60529 Edition 2.2:2013. After testing, the password unlocking function was checked and found to operate normally.
For the IPX9K water protection test, the sample was tested in accordance with ISO 20653:2023. High-temperature water was applied at a pressure of 8–10 MPa from four reference angles: 0°, 30°, 60° and 90°. After testing, the password unlocking function was checked and found to operate normally.
These third-party test results provide documented reference data for locker manufacturers, facility planners, distributors and B2B buyers evaluating RL-9046B for applications where dust and water exposure may need to be considered.
Test Summary
| Test Item | Test Standard | Test Conditions | Post-Test Result |
|---|---|---|---|
| Dust Protection | IEC 60529 Edition 2.2:2013, IP5X | Talcum powder exposure for 8 hours | Password unlocking function: Normal |
| Water Protection | ISO 20653:2023, IPX9K | 80 ± 5°C water, 8–10 MPa, four test angles | Password unlocking function: Normal |
SGS Report Information
| Item | Details |
|---|---|
| Tested Product | Keyless Combination Lock |
| Model | RL-9046B |
| Testing Laboratory | SGS Taiwan Ltd., Reliability Laboratory |
| IPX9K Report No. | HC60076/2026 |
| IPX9K Report Date | July 7, 2026 |
| IP5X Report No. | HC60076A/2026 |
| IP5X Report Date | July 24, 2026 |
Available configurations may include different handing, cams, keying arrangements, and project-specific accessories.
For multi-lock installations, REAL Locks & Security can also review master key and keying system requirements according to the facility access plan.
Available options may vary according to quantity, installation dimensions and project requirements. Please confirm the final configuration with REAL Locks & Security before ordering.
Available project options may include:
- Right-hand or left-hand opening
- Cam configuration
- Override key arrangement
- Project-specific keying
- Master key system planning
- OEM and ODM project support
- Branding and packaging requirements
s for Users, Override Access, and Hierarchical Master Key Management
RL-9046B supports a tiered access structure that c
Combination Acces
an be planned according to different facility management requirements.
Locker or cabinet users normally operate the lock with their personal four-digit combination, eliminating the need to issue individual user keys.
Authorized administrators can use an override key for emergency access, forgotten-code support, locker reassignment, maintenance, and first-level management.
For higher-level access control, a master key system can be configured during the lock procurement and project planning stage. Designated senior managers can then use a master key to open and manage all locks assigned to a specific access level, department, area, or facility.
This hierarchical structure allows access authority to be defined in advance according to the customer’s operational needs:
- Users: Four-digit combination access
- Administrators: Override key for emergency and routine management
- Senior managers: Master key access for all locks within an assigned management level
This combination of user access, override control, and hierarchical master key management is suitable for gyms, schools, workplaces, healthcare facilities, hotels, and other shared-use locker environments requiring both convenience and centralized access control.
Master Key and Keying System Support
For commercial projects requiring centralized key management, RL-9046B can be reviewed as part of a customized keying plan.
Available keying configurations depend on project requirements and must be confirmed before ordering.
Learn more about REAL Locks & Security:
Master Key & Keying System Solutions
Material of Keyless Combination Lock RL-9046B:
Specification Details Model RL-9046B Product Type Mechanical keyless combination locker lock User Access Four-digit combination Code Capacity Up to 10,000 combinations Management Access Override key Front Panel Color Black Frame Finish Platinum Front Panel Material Acrylic Lock Body Material Zinc alloy Cylinder Material Brass Cylinder Type Patented REAL detained disc cylinder Opening Direction Right-hand or left-hand Door / Panel Thickness 1–33 mm Dimensions 98.4 × 40.0 × 78.2 mm Weight 530 g Power Requirement None Dust Test IP5X, IEC 60529 Edition 2.2:2013 Water Test IPX9K, ISO 20653:2023 Third-Party Laboratory SGS Taiwan Ltd.
RL-9046B is designed for commercial lockers, cabinets and shared-use storage applications where users require keyless access and facility managers need an override access method.
Recommended applications include:
- Gym and fitness center lockers
- School and university lockers
- Employee and workplace lockers
- Healthcare facility storage
- Hotel and hospitality lockers
- Recreation center lockers
- Commercial storage cabinets
- Shared-use facility lockers
- Equipment and personnel storage cabinets
Information to Confirm Before Ordering
To help REAL Locks & Security recommend the correct RL-9046B configuration, please provide the following information with your inquiry:
- Locker or cabinet application
- Door or panel material
- Door thickness
- Installation dimensions or technical drawing
- Right- or left-hand opening
- Cam dimensions and locking direction
- Required quantity
- Override key and keying requirements
- Indoor, sheltered or exposed operating environment
- Target country
- OEM, ODM or branding requirements
What is the RL-9046B?
RL-9046B is a mechanical keyless combination lock designed for commercial lockers and cabinets. It combines a four-digit user-set code with override key access for authorized facility personnel.
Has RL-9046B been tested for dust and water protection?
Yes. An RL-9046B sample was tested by SGS Taiwan to IP5X dust test requirements under IEC 60529 Edition 2.2:2013 and IPX9K water protection test requirements under ISO 20653:2023.
The password unlocking function was found to operate normally after both tests.
What does IP59K mean for RL-9046B?
IP59K refers to the combination of the IP5X dust protection test and IPX9K high-pressure, high-temperature water protection test performed separately on the submitted RL-9046B sample.
Is RL-9046B completely waterproof in every installation?
The SGS results apply to the stated test conditions. Final protection performance may also be affected by installation, door structure, mounting conditions, and the actual operating environment.
Buyers should provide application and installation details for project review.
Does RL-9046B require batteries or wiring?
No. RL-9046B is a fully mechanical combination lock and does not require batteries, wiring or electronic programming.
How many combinations does RL-9046B provide?
The four-digit mechanism provides up to 10,000 possible user-set combinations.
What happens if a user forgets the code?
The lock can be opened with the override key. The user may also contact the facility administrator for assistance with opening the lock or retrieving the code.
Can facility managers open the lock with a key?
Yes. Authorized facility managers can use a master key to open and manage multiple RL-9046B locks within the same configured master key system.
Can RL-9046B be installed on both right- and left-hand doors?
Yes. Right-hand and left-hand opening configurations are available. Final handing and cam requirements should be confirmed before ordering.
What door thickness does RL-9046B support?
The current product specification supports door or panel thicknesses from 1 to 33 mm. Installation dimensions should still be reviewed before ordering.
Is RL-9046B suitable for gyms and schools?
Yes. It is designed for shared-use locker and cabinet applications such as gyms, schools, workplaces, healthcare facilities, hotels and recreation centers.
Can REAL Locks & Security support OEM or ODM projects?
Yes. REAL Locks & Security can review OEM and ODM requirements including installation configuration, keying, accessories, branding, packaging and project quantity.
Project feasibility depends on the final specifications.
Discuss Your RL-9046B Locker Lock Project
Send REAL Locks & Security your locker or cabinet application, door thickness, installation dimensions, required quantity and keying requirements.
Our team will review the appropriate RL-9046B configuration for your project.